When a Nachi (Nachi-Fujikoshi) robot teach pendant fails, production stops. Blank screens, unresponsive touch, communication errors, or mode-switching problems can halt entire cells. This practical guide consolidates the most frequent real-world issues reported by technicians and forum users, then gives clear, step-by-step fixes so you can restore operation quickly.
At VICPAS (Guangzhou Vicpas Touch Technology Co., Ltd.), we have supported industrial HMI and robot pendant repair for more than 20 years. With an inventory of over 80,000 models and deep experience in Nachi teach pendant parts, we help maintenance teams minimize downtime with high-quality replacement touchscreens, membrane keypads, LCD displays, housings, cables, E-stop buttons, and JOG dials—all backed by a 12-month warranty and urgent worldwide shipping.
The pendant shows “Abnormal connection – TPE0001 Abnormality occurred by the connection with the controller.” The robot may power on only when a secondary monitor is attached.
If the cable or internal membrane is the culprit, VICPAS stocks direct-fit Nachi pendant cables and membrane keypads for models such as FD11, ROP951, ROP650, and AXTP series. Visit our Nachi Teach Pendant parts page for in-stock options with same-day shipping on many items.
Screen lights up but ignores touches, or only certain areas work.
VICPAS supplies OEM-compatible touch screens and front overlays for Nachi pendants. Our parts are tested for precise fit and durable industrial performance.
Pendant powers on (LEDs may light) but screen stays completely black.
VICPAS carries replacement LCD displays and complete housing assemblies for popular Nachi models, helping you avoid long OEM lead times.
Membrane keys fail, E-stop sticks, or the JOG dial (thumbwheel) does not allow step selection while Enable is held.
Go to:
Constant Setting → 5 Operation/Teaching Conditions → 1 Operating conditions → 8 Step selection with E+up/down keys → set to ENABLE.
For physical key or E-stop failure, replace the membrane keypad or switch. VICPAS offers membrane keypads, E-stop buttons, selector switches, and JOG dials specifically for Nachi teach pendants.
After an error or interruption, the robot refuses to restart motors.
This restores motion task execution in most cases.
Selector switch does not change mode; “safety plug” related errors appear; only Teach or only Auto is available.
W1016 “Manipulator battery warning” or position loss after battery replacement.
Cable failure remains one of the most common root causes across industrial pendants. Always:
VICPAS is a professional HMI parts specialist with over 20 years of experience serving more than 5,000 customers in 110+ countries. We maintain a large inventory of Nachi teach pendant components—including touch screens, membrane keypads, LCD displays, plastic housings, cables, and accessories—ready for fast shipment.
Key advantages:
Browse our full range of Nachi teach pendant replacement parts here:
https://..........com/products2148693/Nachi-Teach-Pendant.htm
Need a quote or technical advice? Contact our team:
Phone: +86-13763341328
Email: sales..........com
By combining systematic diagnosis with quality replacement components, most Nachi teach pendant problems can be fixed the same day. VICPAS is ready to support your next repair with in-stock parts and expert service so your robots stay productive.
This guide is published by the technical team at VICPAS, a global supplier of HMI and robot teach pendant spare parts. For more information about our company and services, visit here.
网络文化经营许可证:浙网文[2013]0268-027号|增值电信业务经营许可证:浙B2-20080224-1 2007-2026 Tradevv.com. All rights reserved.