Follow us :

UniOP eTOP11-0045 HMI Touch Screen Front Overlay

UniOP eTOP11-0045 HMI Touch Screen Front Overlay
UniOP eTOP11-0045 HMI Touch Screen Front OverlayUniOP eTOP11-0045 HMI Touch Screen Front OverlayUniOP eTOP11-0045 HMI Touch Screen Front OverlayUniOP eTOP11-0045 HMI Touch Screen Front OverlayUniOP eTOP11-0045 HMI Touch Screen Front Overlay
group name
UniOP eTOP
Min Order
1 piece
brand name
VICPAS
model
eTOP11-0045
Nearest port for product export
Guangzhou, Hongknog, Shenzhen, Taiwan
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, DEQ, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Westem Union, Cash, Escrow
update time
Fri, 10 May 2024 04:49:14 GMT

Paramtents

  • Brand UniOP

  • Warranty 365 Days

  • Product Line UniOP series

  • Supply eTOP11-0045 Protective Film Touch Screen Repair

  • Model eTOP11-0045

  • Size 5.6 inch

Packging & Delivery

  • Min Order1 piece

Briefing

Exor UniOP eTOP11-0045 Protective Film Touch Screen Panel Repair. 365 Days Warranty-Fully Tested-Factory Prices-Fast Shipping

Detailed

UniOP eTOP series HMI eTOP11-0045 Touch Screen Panel Front Overlay Repair

Order each part separately is available

UniOP series HMI eTOP11-0045 Touchscreen Front Overlay Repair Kit

eTOP11-0045 Touch Film IHM Highlights
• 5.6” STN color display
• 1/4 VGA (320x240 pixel) resolution
• Resistive touchscreen
• Connection to industrial bus systems and Ethernet (requires optional plug-in modules)
• 32 MB user memory
• Compatible with local I/O


The eTOP11 eTOP11-0045 Front Overlay HMI is a low-cost HMI device with touchscreen interface and 5.6” STN graphic display. The compact size and the 1/4 VGA resolution make it an attractive solution where space is a premium without compromising performance.





Specifications:

The table below describes the parameters of the eTOP11-0045 UniOP Touchscreen Overlay.

Part Number: eTOP11-0045
Display Type: STN color LCD
Resolution: 320x240 pixels
Backlight: CCFL
Warranty: 365 Days
Input Power: 24VDC (+10%, -15%)
Operating Temperature: 0 to 45 °C
Display Size: 5.6 in
Touch screen: Resistive
Product Line: UniOP eTOP11 series


Related UniOP Series Part No. :

UniOP eTOP Description Inventory status
eTOP10-0050 UniOP eTOP Touch Screen Monitor Overlay Repair In Stock
eTOP10B-0045 Touch Screen Protective Film UniOP eTOP eTOP10B Available Now
eTOP10B-0050 UniOP eTOP10B Touch Screen Glass Front Overlay In Stock
eTOP10C-0045 UniOP eTOP eTOP10C Touch Protective Film In Stock
eTOP10C-0050 UniOP eTOP10C Touch Screen Overlay Replacement In Stock
eTOP11-0045 HMI Panel Glass Overlay eTOP eTOP11 Repair Available Now
eTOP11-0050 UniOP eTOP Front Overlay Touch Panel Glass In Stock
eTOP11-6550 UniOP eTOP Touch Screen Protective Film Repair Available Now
eTOP11E-0045 UniOP eTOP11E Touch Digitizer Protective Film In Stock
eTOP11E-0050 HMI Panel Glass Overlay eTOP eTOP11E Repair Available Now
eTOP11EB-0045 UniOP eTOP11EB HMI Panel Glass Front Overlay In Stock
eTOP11EB-0050 UniOP eTOP eTOP11EB Touch Protective Film In Stock
eTOP12-0045 HMI Panel Glass Overlay eTOP eTOP12 Repair Available Now
eTOP12-0050 Touch Screen Protective Film UniOP eTOP eTOP12 Available Now
Exor UniOP HMI Description Inventory status


Exor UniOP eTOP HMI Manuals PDF Download:

  • UniOP eTOP05 User Manuals
  • UniOP eTOP05, eTOP05P User Manuals
  • UniOP eTOP06 User Manuals
  • UniOP eTOP06C User Manuals
  • UniOP eTOP10, eTOP11, eTOP12 User Manuals
  • UniOP eTOP10B and eTOP11EB User Manuals
  • UniOP eTOP20B and eTOP21B User Manuals
  • UniOP eTOP30, eTOP32 User Manuals

  • FAQ:

    Question: How to cleaning eTOP11-0045 Touch Panel Glass Overlay IHM faceplates?

    Answer: The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.


    Question: What is Exor UniOP eTOP11-0045 Touchscreen Calibration?

    Answer:

  • Standard calibration:
  • 1. Recall Configuration Mode
  • 2. Touch the CLEAR key on the eTOP11-0045 screen until a small round symbol will appear on the top right corner of the screen
  • 3. touch and hold the symbol until it will move to the low left corner of the eTOP11-0045 screen
  • 4. touch and hold the symbol until the indication to touch the ← key will be displayed on the screen
  • 5. touch and hold the key ← until the indication to touch the ↓ key will be displayed on the screen
  • 6. touch and hold the key ↓ until the indication to touch the Enter key will be displayed on the screen
  • 7. touch and hold the Enter key until the panel will switch to Operation Mode (if a valid project is loaded in the memory)
  • Emergency calibration.
  • The Emergency calibration procedure should be used in all cases when it would result not possible to go to calibration using the standard procedure.
  • 1. Switch of the unit
  • 2. turn on the unit
  • 3. tap in the middle of the touchscreen with a frequency of about one second until the operator panel will enter the Calibration Mode
  • 4. perform the standard calibration procedure.

  • Common misspellings: 

    eTOP11-005
    TOP11-0045
    eTOPll-0045
    eTOP11-0054
    eTOP110-0045