Follow us :

UniOP eTOP02C-0050 HMI Touch Screen Front Overlay

UniOP eTOP02C-0050 HMI Touch Screen Front Overlay
UniOP eTOP02C-0050 HMI Touch Screen Front OverlayUniOP eTOP02C-0050 HMI Touch Screen Front OverlayUniOP eTOP02C-0050 HMI Touch Screen Front OverlayUniOP eTOP02C-0050 HMI Touch Screen Front OverlayUniOP eTOP02C-0050 HMI Touch Screen Front Overlay
group name
UniOP eTOP
Min Order
1 piece
brand name
VICPAS
model
eTOP02C-0050
Nearest port for product export
Guangzhou, Hongknog, Shenzhen, Taiwan
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, DEQ, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Westem Union, Cash, Escrow
update time
Fri, 10 May 2024 07:56:52 GMT

Paramtents

  • Brand UniOP

  • Warranty 365 Days

  • Product Line UniOP eTOP02C series

  • Supply eTOP02C-0050 Protective Film Touch Screen Repair

  • Model eTOP02C-0050

  • Size 3.5 inch

Packging & Delivery

  • Min Order1 piece

Briefing

UniOP eTOP02C-0050 Protective Film Touch Screen Panel Repair. 365 Days Warranty-Fully Tested-Factory Prices-Fast Shipping

Detailed

UniOP eTOP02C series HMI eTOP02C-0050 Touch Screen Panel Front Overlay Repair

Order each part separately is available

UniOP series HMI eTOP02C-0050 Touchscreen Front Overlay Repair Kit

eTOP02C-0050 Touch Screen Protective Film IHM Highlights
• 3.5” monochrome display with white LED backlight
• 1/4 VGA (320x240 pixel) resolution
• Portrait mode operation
• Resistive eTOP02C-0050 touchscreen
• Connection to industrial bus systems and Ethernet (requires optional plug-in modules)
• 512 KB user memory


The eTOP02C eTOP02C-0050 HMI Panel Glass Front Overlay Terminal is a low-cost HMI device with eTOP02C-0050 touchscreen interface and 3.5” monochrome graphic display. The very compact size and the 1/4 VGA resolution make it the optimal solution for a tight budget without compromising quality and performance. Portrait mode (vertical mode) operation enhances the flexibility and makes the product suitable to even more application areas.





Specifications:

The table below describes the parameters of the eTOP02C-0050 UniOP Touchscreen Overlay.

Part Number: eTOP02C-0050
Display Type: TFT LCD
Resolution: 320x240 pixel
Backlight: LED
Warranty: 365 Days
Input Power: 24VDC (+10%, -15%)
Operating Temperature: 0 to 50 °C
Display Size: 3.5 in
Touch screen: Resistive
Product Line: UniOP eTOP02C series


Related UniOP Series Part No. :

UniOP eTOP Description Inventory status
eTOP02-0045 UniOP eTOP Touch Screen Monitor Overlay Repair In Stock
eTOP02-0046 Touch Screen Protective Film UniOP eTOP eTOP02 Available Now
eTOP02-0050 UniOP eTOP02 Touch Screen Glass Front Overlay In Stock
eTOP02C-0045 UniOP eTOP eTOP02C Touch Protective Film In Stock
eTOP02C-0050 UniOP eTOP02C Touch Screen Overlay Replacement In Stock
eTOP03-0045 HMI Panel Glass Overlay eTOP eTOP03 Repair Available Now
eTOP03-0046 UniOP eTOP Front Overlay Touch Panel Glass In Stock
eTOP03-0050 UniOP eTOP Touch Screen Protective Film Repair Available Now
eTOP04C-0045 UniOP eTOP04C Touch Digitizer Protective Film In Stock
eTOP04C-0046 HMI Panel Glass Overlay eTOP eTOP04C Repair Available Now
eTOP04C-0050 UniOP eTOP04C HMI Panel Glass Front Overlay In Stock
eTOP05-0045 UniOP eTOP eTOP05 Touch Protective Film In Stock
eTOP05-0345 eTOP eTOP05 Front Overlay Touch Digitizer Glass Available Now
eTOP05-D245 HMI Panel Glass Overlay eTOP eTOP05 Repair Available Now
Exor UniOP HMI Description Inventory status


Exor UniOP eTOP HMI Manuals PDF Download:

  • UniOP eTOP02 User Manuals
  • UniOP eTOP03 Datasheet
  • UniOP eTOP04C Datasheet
  • UniOP eTOP05 User Manuals
  • UniOP eTOP05, eTOP05P User Manuals
  • UniOP Manual
  • UniOP User's Manual
  • UniOP Installation Guide
  • UniOP Touch & Controls PDF
  • UniOP Universal Operator Panels Installation Guide

  • FAQ:

    Question: How to cleaning eTOP02C-0050 Touch Panel Glass Overlay IHM faceplates?

    Answer: The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.


    Question: What is Exor UniOP eTOP02C-0050 Touchscreen Calibration?

    Answer:

  • Standard calibration:
  • 1. Recall Configuration Mode
  • 2. Touch the CLEAR key on the eTOP02C-0050 screen until a small round symbol will appear on the top right corner of the screen
  • 3. touch and hold the symbol until it will move to the low left corner of the eTOP02C-0050 screen
  • 4. touch and hold the symbol until the indication to touch the ← key will be displayed on the screen
  • 5. touch and hold the key ← until the indication to touch the ↓ key will be displayed on the screen
  • 6. touch and hold the key ↓ until the indication to touch the Enter key will be displayed on the screen
  • 7. touch and hold the Enter key until the panel will switch to Operation Mode (if a valid project is loaded in the memory)
  • Emergency calibration.
  • The Emergency calibration procedure should be used in all cases when it would result not possible to go to calibration using the standard procedure.
  • 1. Switch of the unit
  • 2. turn on the unit
  • 3. tap in the middle of the touchscreen with a frequency of about one second until the operator panel will enter the Calibration Mode
  • 4. perform the standard calibration procedure.

  • Common misspellings: 

    eTOP02-0050
    TOP02C-0050
    eTOP0C2-0050
    eT0P02C-0050
    eTOP02C--0050