Follow us :

Membrane keyboard for 2711P-K12C4D9 membrane keypad switch

Membrane keyboard for 2711P-K12C4D9 membrane keypad switch
Membrane keyboard for 2711P-K12C4D9 membrane keypad switchMembrane keyboard for 2711P-K12C4D9 membrane keypad switchMembrane keyboard for 2711P-K12C4D9 membrane keypad switchMembrane keyboard for 2711P-K12C4D9 membrane keypad switchMembrane keyboard for 2711P-K12C4D9 membrane keypad switch
group name
Panelview Plus 6
Min Order
1 piece
brand name
VICPAS
model
2711P-K12C4D9
Nearest port for product export
Guangzhou, Hongknog, Shenzhen, Taiwan
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, DEQ, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Westem Union, Cash, Escrow
update time
Sun, 24 Nov 2024 10:11:08 GMT

Paramtents

  • Warranty 180 Days

  • Brand Rockwell Automation Allen Bradley

  • Product Line Panelview Plus 6

  • Supply Panelview Plus 6 Terminals Membrane keypad

  • Size 12.1 inch

  • model 2711P-K12C4D9

  • Parts Keypad Switch Plastic Shell LCD Display

Packging & Delivery

  • Min Order1 piece

Briefing

Panelview Plus 6 Operator Panel Keypad HMI Case LCD Display Panel. 365-day Warranty-Fully Tested-Factory Prices-Fast Shipping

Detailed

2711P-K12C4D9 Panelview Plus 6 Terminals Membrane Keypad, Protection Board, Label, LCD Display Panel, Housing, Gasket Repair Replacement

Order each part separately is available

2711P-K12C4D9 Panelview Plus 6 Terminals Membrane Keypad, Protection Board, Label, Plastic Shell, LCD Display, Gasket and Mounting Clips Repair Replacement


The 2711P-K12C4D9 display system comes with the FAT 16, FAT32, and 64 Megabytes versions. The 2711P-K12C4D9 display comes in an open architecture and also supports the .Net Compact Framework, though it is not installed at the factory. The approximate dimensions of the 2711P-K12C4D9 terminal are 11.12 x 16.36 x 2.18 inches and weighs 7.6 lbs. or 3.4 kg. The enclosure rating of this terminal is NEMA Type 12, 13, 4X, IP54, and IP65.


The keypad of the 2711P-K12C4D9 PanelView Terminal has an actuation rating of 1 million press. Further, there are 40 function keys, navigation keys, and numeric keys strategically arranged around the LCD. The 2711P-K12C4D9 is an Allen-Bradley PanelView 6 color display computer that runs the Windows CE 4.1 operating system. The application software for the 2711P-K12C4D9 is the FactoryTalk View ME Station Software, Version 3.20.

For communications, the interfaces that come with 2711P-K12C4D9 include 1 10/100 megabytes per seconds Ethernet port, 1 D89 RS-232 interface, and it also supports the ControlNet, DH+™, DH-485, Remote I/O, and DeviceNet networks as optional add-on communication modules. For the supported interfaces, the 2711P-K12C4D9 supports 1 CF Type 1 CompactFlash card on the SD slot, the 2 USB-A, V1.1 USB ports, and the I PCI, 3.3/5 Volts with a 32-bit PCI.


The base unit terminal has built-in Ethernet and RS-232 communication ports and the communication module known as the 2711P-RN20 provides an additional Ethernet port, a Standard Communication (Ethernet and RS-232) port, and scheduled and unscheduled communication capabilities.




Specifications:

The table below describes the parameters of the Panelview Plus 6 2711P-K12C4D9 terminals Parts.

Part Number: 2711P-K12C4D9
Display Size: 12.1 inches
Display Color: Amber
Warranty: 180 days Warranty
Product Line: Panelview Plus 6
Input Type: Keypad
Mounting Position: vertical
Communication: Ethernet and RS-232
Communication: ControlNet
Software: FactoryTalk


Related Allen Bradley Panelview Plus 6 Terminals Part No. :

PanelView Plus 6 HMI Description Inventory status
2711P-K6M20A8 Allen Bradley Panel Plus 6 Membrane Keypad LCD Display Plastic Case In Stock
2711P-K6M20D8 Allen Bradley Panel View Plus 6 Keypad LCD Screen Cover Replacement Available Now
2711P-K7C4A8 PanelView Plus 6 Membrane Switch LCD Display Plastic Shell Replacement In Stock
2711P-K7C4A9 PanelView Plus 6 Membrane Keyboard Keypad LCD Screen HMI Case In Stock
2711P-K7C4D8 PanelView Plus 6 Membrane Keypad Switch LCD Display Housing Repair In Stock
2711P-K7C4D9 Allen Bradley PanelView Plus 6 Operator Panel Keypad LCD Display Enclosure In Stock
2711P-K10C4A8 PanelView Plus 6 Operator Keyboard LCD Display Plastic Case Replacement Available Now
2711P-K10C4A9 Allen Bradley Panel View Plus 6 Keyboard Membrane LCD Display Case In Stock
2711P-K10C4D8 PanelView Plus 6 Membrane Keyboard Repair Kit Plastic Shell LCD Display Available Now
2711P-K10C4D9 PanelView Plus 6 Membrane Keyboard Keypad LCD Display Case Repair In Stock
2711P-K12C4A8 Allen Bradley Panel View Plus 6 Keypad Plastic Case LCD Display Screen In Stock
2711P-K12C4A9 PanelView Plus 6 Switch Membrane HMI Case LCD Display Screen In Stock
2711P-K12C4D8 PanelView Plus 6 Touch Screen Keypad Front Cover LCD Display Panel Available Now
2711P-K12C4D9 Allen Bradley PanelView Plus 6 Membrane Keyboard Plastic Case LCD Screen In Stock
2711P-K15C4A8 PanelView Plus 6 Membrane Keyboard Keypad Housing LCD Display Screen Available Now
2711P-K15C4A9 Allen Bradley Panel View Plus 6 Operator Panel Keypad Front Cover LCD Display In Stock
2711P-K15C4D8 Allen Bradley Panel View Plus 6 Keypad Plastic Shell LCD Screen Repair In Stock
2711P-K15C4D9 PanelView Plus 6 Membrane Switch Plastic Case LCD Display Replacement In Stock
AB PanelView Plus 6 Description Inventory status

AB Panelview Plus 6 Manuals PDF Download:

  • 2711P-K12C4D9 Terminals User Manuals
  • Allen Bradley PanelView Plus 6 Terminals Operator Panel User Manual
  • panelview plus 6 battery replacement Installation Instructions
  • PanelView Plus 6 Terminals and Display Modules
  • PanelView Plus Operator Terminals 6 dimensions datasheet manual


  • FAQ:

    Question: How to change the Decimal Separator for Numeric Formats?

    Answer: You can change the decimal separator used in numerics for the current language. The default decimal separator is a period.
    1. Select Terminal Settings>Time/Date/Regional Settings>Regional Settings>Numeric Format.
    The field shows the default decimal separator. The field will accept a separator up to three characters.
    2. Enter up to three characters for the new separator.
    3. Click OK.

    Question: What steps need to be connectted the terminal 2711P-K12C4D9 to AC power?

    Answer:

    1. Verify that the terminal is not connected to a power source.
    2. Secure the AC power wires to the terminal block.
    Follow the markings on terminal blocks and terminal for proper connections.
    3. Secure the protective earth/ground wire to the marked position of the power input terminal block.
    4. On the 700 to 1500 devices, also secure the functional earth/ground wire to the functional earth terminal screw on the back of the display to ground bus.
    5. Apply AC power to the terminal.


    Question: How to replace a 2711P-K12C4D9 communication module?

    Answer:
    1. Disconnect power from the terminal.
    2. Disconnect the communication cables from the module.
    3. Loosen the three screws that secure the communication module to the terminal.
    4. Carefully lift the communication module away from the terminal and set aside.
    5. Install the new communication module.


    Question: How to delete Log Files from Terminal 2711P-K12C4D9?

    Answer:
    You can delete log files, alarm history files, and alarm status files from the System Default location on the terminal.
    1. Select Terminal Settings>File Management>Delete Files>Delete Log Files.
    You are asked to confirm the deletion of the files.
    Do you want to delete all of the FactoryTalk View ME Station Log Files?
    2. Select Yes or No.Log files not located in the System Default location will not be deleted.



    Common misspellings: 

    271P-K12C4D9
    2711P-K1C4D9
    2711P-K12C9D
    2171P-K12C4D9
    2711PK-12C4D9
    2711P-K21C4D9
    2711PP-K12C4D9
    2711P--K12C4D9
    2711P-K12C4ADD9