Paramtents
Warranty 365 Days
Brand Rockwell Automation Allen Bradley
Product Line Panelview Plus 1500
Supply Panelview Plus 1500 Touchscreen Overlay FrontCover
Size 15 inch
model 2711P-T15C10D2
Parts Touchscreen Panel Housing Protective Film LCD
Packging & Delivery
Min Order1 piece
Briefing
Detailed
Order each part separately is available
The 2711P-T15C10D2 touch screen glass front overlay Front Cover has a Logic module that has an internal compact flash with the open Windows CE operating system, pre-installed FactoryTalk View ME software, and a flash memory of 256MB. Its Logic module also has a memory card slot for system memory expansion. The Allen-Bradley 2711P-T15C10D2 terminal is part of the PanelView Plus series of terminals that are specially designed for industrial use and engineered for strength and longevity. 2711P-T15C10D2 terminal is rated for excessive temperatures, protected against common industrial pollutants, and it is designed for use in outdoor environments. The 2711P-T15C10D2 protective film Plastic Shell touchscreen can also operate at very low temperatures where ordinary terminals would either shut down or become damaged.
The 2711P-T15C10D2 terminal gives high-performance standards even under extreme temperatures. The 2711P-T15C10D2 Housing touch panel overlay offers a high level of operation without compromising on the sturdiness of the construction. The screen size of the display unit is 15 inches and the display has color graphics with a 640 x 480 resolution and 18-bit graphics that offer great utility for the users. The display units in this series are considered to be excellent for Ethernet systems connected via the integrated communication ports.
The 2711P-T15C10D2 is a PanelView Plus 1500 Color Terminal manufactured by Allen-Bradley. It is a Human-Machine Interface (HMI) device made for the visual presentation of industrial processes and machines in high-detailed graphics. It can also process and store a large amount of historical data and log events for future use and checking. The 2711P-T15C10D2 is a versatile 15-inch TFT Color Touch Display from Rockwell Automation. The ControlNet communication module is an integrated option of the terminal. With this option, your terminal and its data will be available on the network (extendable up to 99 nodes). Over this module, this HMI becomes available to PLC-5C and ControlLogix PLC series industrial controllers.
The 2711P-T15C10D2 HMI touch screen is a PanelView Plus 1500 touchscreen with a 15-inch color display. The touchscreen assists users in keying in information and data into their machines with ease. It features the standard communication option of Ethernet and USB ports. It also has a DH+/DH-485-communication module. This terminal comes with a CE Logic module that has 64MB flash memory used to store large amounts of information and AC power. This part allows for flexible and convenient choices of operator input because of its keypad combination terminals.
The table below describes the parameters of the Panelview Plus 1500 2711P-T15C10D2 Operator Panel Parts
Part Number: | 2711P-T15C10D2 |
Display Size: | 15 inches |
Display Color: | Amber |
Warranty: | 365 days Warranty |
Product Line: | Panelview Plus 1500 |
Input Type: | Touchscreen |
Mounting Position: | vertical |
Communication: | Ethernet and RS-232 |
Communication: | ControlNet |
Software: | FactoryTalk |
Related Allen Bradley Panelview Plus Terminals HMI Part No. :
PanelView Plus HMI | Description | Inventory status |
2711P-T7C1D2 | PanelView Plus Touch Membrane LCD Display Protective Film Housing | In Stock |
2711P-T7C1D6 | PanelView Plus HMI Touch Glass Protective Film LCD Display Screen Plastic Case | Available Now |
2711P-T7C10D2 | Panel View Plus HMI Panel Glass LCD Screen Front Overlay HMI Case | In Stock |
2711P-T7C10D6 | Panel View Plus Touchscreen LCD Display Protective Film Plastic Case | In Stock |
2711P-T10C1D2 | PanelView Plus Touch Screen Protective Film LCD Display Housing | In Stock |
2711P-T10C1D6 | PanelView Plus Touch Screen Front Overlay LCD Display Screen HMI Case | In Stock |
2711P-T10C10D2 | PanelView Plus Touch Screen Protective Film LCD Display Panel Plastic Cover Body | Available Now |
2711P-T10C10D6 | Allen Bradley PanelView Plus Touchscreen LCD Front Overlay Plastic Cover | In Stock |
2711P-T12C1D2 | PanelView Plus Touch Membrane LCD Display Front Overlay Housing | Available Now |
2711P-T12C1D6 | Panel View Plus HMI Touch Glass Front Overlay LCD Display Enclosure | In Stock |
2711P-T12C10D2 | PanelView Plus Touch Screen Panel Protective Film LCD Display Plastic Case | In Stock |
2711P-T12C10D6 | PanelView Plus Touch Membrane Front Overlay LCD Display Plastic Shell | Available Now |
2711P-T15C1D2 | PanelView Plus Touch Screen LCD Display Protective Film Plastic Cover Body | Available Now |
2711P-T15C1D6 | Panel View Plus Front Overlay Touch Screen LCD Display Plastic Case | In Stock |
2711P-T15C10D2 | Allen Bradley Panel View Plus Touch Screen Front Overlay LCD Display HMI Case | In Stock |
2711P-T15C10D6 | PanelView Plus Touch Screen Protective Film LCD Display Housing | In Stock |
Allen Bradley PanelView Plus | Description | Inventory status |
Question: What is the 2711P-K15C4A7 Panelview Plus 1500 HMI parts price?
Answer: Submit a fast quote, send VICPAS an email for best price.
Question: How to replace 2711P-T15C10D2 Display Module Bezel?
Answer:
1. Make sure new bezel is free of lint and marks before attaching.
2. Attach the following connectors. The number of connectors varies by model.
• IrDa connector
• Function Key connector
3. Place the back of the Display Module over the new bezel. Be careful not to pinch any of the cables.
Allow the Touch Screen connector to extend out of the access opening.
4. Attach Touch Screen connector.
5. Replace the sealing gasket.
6. Attach screws that secure Display Module to bezel and tighten to a torque of 1.35 - 1.58 N•m (12-14 in-lb).
7. On touch screen terminals, re-attach the small metal plate to the back of the Display Module using 2 screws.
Question: How to edit the 2711P-T15C10D2 device address of the logic controller?
Answer:
1. From the RSLinx Configuration screen, select a device node.
2. Select the Edit Device button.
A screen opens showing the name of the device and its current node address.
3. To modify the device address, press the Device Address button.
The Input Panel opens showing the current address.
4. Using the Input Panel, modify the address and then select the Enter button.
Question: If the terminal display is dim or unreadable, what should we do?
Answer:
• Check the brightness setting of the display. From Configuration mode on the terminal, access Terminal Settings>Display Intensity.
• Check the Screen Saver settings. The backlight may be turning off or dimming the display unexpectedly. From Configuration mode on the terminal, access Terminal Settings>Display>Screen Saver.
2711P-T5C10D2
711P-T15C10D2
2711P-T151C0D2
2711P-T15C1oD2
27111P-T15C10D2