Paramtents
Brand Mettler Toledo
Warranty 365 Days
Supply MX12001L MX16001L HMI Touch Screen LCD Display
Supply MX32001L MX32000L HMI Panel Glass LCD Screen
Shipping 2-4 workdays
Packging & Delivery
Min Order1 piece
Briefing
Detailed
Order each part separately is available
Mettler-Toledo MX12001L MX16001L MX32001L MX32000L HMI Touch Glass LCD Display Analytical Balances provide superior weighing accuracy for laboratory applications. The Backlit Draft Shield enhances visibility, enabling precise micro-dosing. Featuring a high readability and weighing capacities up to 32.2kg, the MX12001L MX16001L MX32001L MX32000L LCD Screen Touch Screen Monitor balances ensure high repeatability and reliability. SmartPan technology minimizes environmental disturbances and FACT automatic internal adjustment maintains measurement accuracy. The 7-inch touchscreen with built-in applications and statistical tools streamlines workflows. With an energy-saving mode, efficiency is maximized.
Power-Saving Mode
To save energy and costs, as well as protect the environment, you can configure when your balance will automatically go into its ultra-low power mode, for example overnight and at weekends. It will also warm up to be ready for work at the time you choose.
Durable Construction
The full metal housing protects the weighing cell from impacts and environmental influences and is resistant to harsh chemicals, including acetone.
Comprehensive Service Offering
Our services include installation and qualification, calibration, maintenance, and routine testing to ensure your balance is fit for purpose and meets industry standards and regulatory requirements. Customize your service package to meet your precise needs.
VICPAS supplies METTLER TOLEDO MX12001L MX16001L MX32001L MX32000L LCD Display and Touch Screen Tablet with 365 days warranty and supports Urgent Worldwide Shipping.
The table below describes the parameters of the Mettler Toledo MX12001L MX16001L MX32001L MX32000L Touch Screen Panel LCD Screen Parts.
Brand: | Mettler Toledo |
Model Number: | MX12001L MX16001L |
Display: | 7" colour TFT touchscreen |
Warranty: | 12 Months Warranty |
Adjustment: | Internal (automatic/FACT) |
Model Number: | MX32001L MX32000L |
Overvoltage Category: | II |
Pollution Degree: | 2 |
Related Mettler Toledo HMI Part No. :
Mettler-Toledo Scale | Description | Inventory status |
MX2002 | Mettler-Toledo HMI Touch Screen Film LCD Display Panel | In Stock |
MX4002 | METTLER TOLEDO Touch Panel LCD Display Replacement | Available Now |
MX6002 | Mettler-Toledo LCD Screen Touch Screen Glass Repair | In Stock |
MX6002DR | Mettler Toledo HMI Touch Screen Monitor LCD Display | In Stock |
MX12002 | Mettler Toledo LCD Display Screen Touch Screen Panel | Available Now |
MX6001 | METTLER TOLEDO Touch Digitizer LCD Display Repair | In Stock |
MX8001 | Mettler-Toledo Touch Screen Display LCD Screen Repair | Available Now |
MX12001L | METTLER TOLEDO HMI Touch Screen Panel LCD Display | Available Now |
MX16001L | Mettler Toledo LCD Display Touch Screen Replacement | In Stock |
MX32001L | Mettler-Toledo Touch Screen Tablet LCD Display Screen | Available Now |
MX32000L | METTLER TOLEDO MMI Touch Screen LCD Display Repair | In Stock |
Mettler-Toledo Terminal | Description | Inventory status |
Question: What should I do if the Mettler-Toledo MX12001L MX16001L MX32001L MX32000L Touch Screen Display LCD Screen balance does not return to zero after removing the weight?
Answer: If the balance does not reset to zero after removing the sample, follow these troubleshooting steps:
● Check for residual material: Ensure that no small particles, dust, or static charge remain on the weighing pan. Clean the pan if necessary.
● Manually tare the balance: Press the "Zero" or "Tare" button to force the balance to reset.
● Check for environmental disturbances: Drafts, vibrations, or unstable surfaces can prevent the balance from properly returning to zero. Place it on a stable, vibration-free surface away from airflow sources.
● Calibrate the balance: If the issue persists, perform an internal (FACT) or external calibration using a certified weight.
● Restart the balance: Power off the balance, wait a few minutes, and turn it back on to see if the issue resolves.
● Check system settings: Verify if automatic zero tracking is enabled in System Settings > Weighing Settings. If disabled, enable it.
● Contact technical support: If none of these steps resolve the issue, there may be a sensor or weighing cell problem. Contact technical support for further assistance.
Question: What to do if communication with the weighing module is not possible?
Answer: Perform a balance reset. Reinstall the balance software. If the issue persists, contact the METTLER TOLEDO service representative.
网络文化经营许可证:浙网文[2013]0268-027号|增值电信业务经营许可证:浙B2-20080224-1 2007-2025 Tradevv.com. All rights reserved.