Follow us :

GFX-1260 12.1 Touch Digitizer Glass LCD Display Panel

GFX-1260 12.1 Touch Digitizer Glass LCD Display Panel
GFX-1260 12.1 Touch Digitizer Glass LCD Display PanelGFX-1260 12.1 Touch Digitizer Glass LCD Display PanelGFX-1260 12.1 Touch Digitizer Glass LCD Display PanelGFX-1260 12.1 Touch Digitizer Glass LCD Display PanelGFX-1260 12.1 Touch Digitizer Glass LCD Display Panel
group name
Trimble
Min Order
1 piece
brand name
VICPAS
model
GFX-1260 12.1
Nearest port for product export
Guangzhou, Hongknog, Shenzhen, Taiwan
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, DEQ, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Westem Union, Cash, Escrow
update time
Sat, 22 Feb 2025 02:11:03 GMT

Paramtents

  • Brand Trimble

  • Warranty 365 Days

  • Product Line Trimble series

  • Supply Trimble GFX-1260 12.1 Touch Panel LCD Display

  • Size 12.1 inch

  • Model Trimble GFX-1260 12.1

Packging & Delivery

  • Min Order1 piece

Briefing

Trimble GFX-1260 12.1 LCD Display Screen Touch Digitizer Glass. 365 Days Warranty-Fully Tested-Factory Prices-Fast Shipping

Detailed

Trimble GFX-1260 12.1 Touch Screen Tablet LCD Display Panel Replacement

Order each part separately is available

Trimble GFX-1260 12.1 Touch Screen Panel Glass LCD Display Repair Part

The Trimble® GFX-1260 12.1 is an in-cab touchscreen display that provides affordable guidance, steering and precision agriculture functionality. The Trimble GFX-1260 12.1 LCD Screen Touch screen panel glass includes a built-in GPS receiver that you can upgrade to receive GLONASS satellite signals. The Trimble GFX-1260 12.1 Touch Panel LCD Display Screen is used in agricultural applications to maximize efficiency in activities such as planting, spraying, spreading and strip tilling.


VICPAS supplies Trimble GFX-1260 12.1 Trimble Touchscreen glass and LCD Display Panel with 365 Days warranty and support Urgent Worldwide Shipping.




Specifications:

The table below describes the parameters of the Trimble GFX-1260 12.1 HMI Panel Glass.

Part Number: GFX-1260 12.1
Screen diagonal: 12.1 inch
Warranty: 365 Days
Product Line: Trimble Series
Input Power: +24 VDC +/-20%
Resolution:
Storage Temperature: -20°C to 60°C
Display Size: STN


Related Trimble Series Part No. :

Trimble HMI Description Inventory status
GFX-1060 Trimble Touch Screen Glass LCD Display Replacement In Stock
CASE IH AFS PRO 1200 Display Trimble Touch Panel Glass Replacement Repair Available Now
GFX-1260 12.1 Trimble Touch Screen Panel Repair Replacement In Stock
GFX-750 Trimble LCD Display Panel Touch Screen Monitor Replacement Available Now
XCN-1050 121000 Trimble LCD Screen Touch Digitizer Repair In Stock
XCN-1060 134000 Trimble HMI Touch Screen Organizer LCD Display Screen Replacement In Stock
XCN-1260 137000 12.1 Trimble Touch Panel Glass Replacement In Stock
XCN-750 124000 Trimble LCD Display Panel Touch Screen Panel Repair Replacement Available Now
Trimble HMI Description Inventory status


Trimble Series HMI Manuals PDF Download:

  • GFX-1260_Datasheet_ENG
  • XCN-1050_Quick_Reference_Card
  • Brochure - Trimble Field Solutions - English (USL)
  • Product Comparison -Trimble Total Stations

  • FAQ:

    Question: What are the specific steps to calibrate the Trimble GFX-1260 12.1?

    Answer: To calibrate the Trimble GFX-1260 display, follow these specific steps:

    Pre-Calibrating Steps
    1. Setup Vehicle Profile:
    - Ensure that the vehicle profile is completely set up in the Precision-IQ application.

    2. Warm Up:
    - Allow the vehicle to warm up to ensure all systems are functioning correctly.

    Calibration Process
    3. Access Calibration Menu:
    - From the home screen of the GFX-1260, navigate to the "Settings" menu and select "Calibration."

    4. Calibrate Guidance Settings:
    - Select "Guidance" and follow the prompts to calibrate steering settings. This typically involves driving in a straight line and then turning to establish reference points for guidance.

    5. Implement Calibration:
    - If using an implement, go to the "Implement" screen.
    - Select the implement you want to calibrate and tap on "Calibrate."
    - Follow on-screen instructions to enter parameters such as application rate, speed, and meter revolutions.

    6. Spinner Speed Calibration (if applicable):
    - Navigate to the spinner speed control settings.
    - Enter target values for spinner speed and follow prompts to complete calibration.

    7. Save Calibration Settings:
    - Once satisfied with the calibration results, save your settings by tapping the green check mark.

    8. Final Checks:
    - Review all calibrated settings to ensure they align with operational requirements.

    Post-Calibration
    9. Test Run:
    - Conduct a test run in the field to verify that all calibrated settings are functioning correctly during operation.

    10. Adjust as Necessary:
    - If any discrepancies are observed during the test run, return to the calibration menu and make necessary adjustments.

    For detailed guidance, refer to the [Precision-IQ User Guide] or consult an authorized Trimble dealer for assistance.